What is the suction pressure of R-404A?

What is the suction pressure of R-404A?

R404a Refrigerant Pressure Chart

Temperature (Fahrenheit) Temperature (Celsius) R404a Pressure
– 40°F – 40°C 4.3 psi
– 35°F – 37.2°C 6.8 psi
– 30°F – 34.4°C 9.6 psi
– 25°F – 31.7°C 12.7 psi

What should the high and low side pressures be for R-404A?

When the temperature inside the freezer is at about 0°F, the low side pressure should be 8-10PSIG for R404A charged units. Refrigerators should pull down to 35°F in about 20 minutes when located in an ambient of about 75 °F.

What is the boiling point of R-404A?

-46 °C
R404A/Boiling point

How do you charge a R-404A system?

If R-404A or R-507 is used, liquid charging is mandatory. R-404A and R-507 refrigerant cylinders have a dip tube and liquid is charged with the cylinder upright. Break the final vacuum by charging liquid refrigerant into the receiver outlet valve access or the area of liquid line downstream from the receiver outlet.

What are normal pressures for 407c?

R-407C Pressure Chart

Temp (F) Temp (C) Liquid Pressure (PSIG)
89.6 32 192.86
93.2 34 203.74
96.8 36 215.04
100.4 38 226.77

What should superheat be for 404A?

When ambient air temp (Outside air temp) is 75-85 degrees the superheat should be 12-15 degrees, if the ambient temperature is 85 degrees or over the superheat should be 8-12 degrees.

Is 404A flammable?

R-404A is classified as non-flammable by the U.S. organization ASHRAE. However, if R-404A is pressurized after being mixed with air, there is a possibility that it could become flammable. R-404A must never be mixed with air under any circumstances.

What refrigerant will replace R404A?

What are the best replacements for R404A? For cold rooms and other small to medium commercial refrigeration applications, R448A and R449A and R452A or R134a are excellent alternatives to R404A, with from 50 to 65% reduction in GWP.

Can you mix r134 with r404?

Re: Accidentally mixed R404A with R134a Vacuum is not necessary because R404a consists of R134a. It will never work and your TEV or capillary is not designed for this refrigerant. If you want to destroy your compressor, let it run this way.

What is refrigerant charging?

The refrigerant charging in Refrigeration system or AC system is done because refrigeration effect in it cause decrease in refrigerant due to leakage of gas. The leak must be detected and rectified in the refrigeration system before the refrigerant is charged.

When did the refrigerant R-404A come out?

R-404A Pressure Chart R-404A rose to prominence in the late 1990’s with the phasing out of CFC and HCFC refrigerants like R-12 and R-502. There had to be a replacement for the Ozone damaging refrigerants of the past and the successor was the HFC R-404A that we all know of today. 404A’s reign however was short lived.

Which is the HFC in Freon 404a refrigerant?

Freon™ 404A (R-404A) is a blended hydrofluorocarbon (HFC) refrigerant comprised of R-125, R-134a, and R-143a. It was designed to replace R-502 and R-22 used in commercial refrigerator equipment for low and medium temperature ranges.

Which is better 5 Freon 404a or R-502?

5 Freon™ 404A (R-404A) offers the best overall properties when compared with R-502. Capacity and efficiency values should be equivalent to R-502, and compressor discharge temperatures may be up to 9 °C (14 °F) lower than R-502, which may equate to longer compressor life and better lubricant stability.

What is the pressure of a R404A gas?

R404A Pressure Temperature Chart 14 9.28 8.27 119.92 9.16 8.15 118.19 16 9.82 8.81 127.74 9.70 8.69 125.97 18 10.39 9.37 135.89 10.26 9.25 134.08 20 10.97 9.96 144.41 10.84 9.83 142.55 22 11.58 10.57 153.25 11.45 10.44 151.37 24 12.22 11.21 162.47 12.09 11.07 160.56 26 12.88 11.87 172.07 12.75 11.73 170.11 28 13.57 12.56 182.05 13.43 12.42 180.06